Kern-sohn SD 3KN150 User Manual

Browse online or download User Manual for Measuring instruments Kern-sohn SD 3KN150. KERN & SOHN SD 3KN150 User Manual [en] [fr] [de]

  • Download
  • Add to my manuals
  • Print
  • Page
    / 4
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 0
Sauter GmbH
Ziegelei 1
D-72336 Balingen
Tel: +49-[0]7433- 9933-199
Fax: +49-[0]7433-9933-149
Internet: www.kern-sohn.com
Instruction Manual
SD
SD-BA-e-1213 1
Model: SD, Spring Tester
Thank you for buying a SAUTER Spring Tester. We hope
you are pleased with your high quality force gauge with its
big functional range. If you have any queries, wishes or
helpful suggestions, do not hesitate to call our service
number.
1. Working Conditions
10°C to 30°C / 15% up to 80% humidity
2. Operation
a. Display
(1) Measuring Result
(2) Measuring Units
(3) Activation of PRINT Function
(4) Indication of power charging status
(5) PEAK or AUTO-PEAK Mode
(6) Average value of stored peak values
(7) Force direction
(8) Occupancy of storing spaces
(9) AVERAGE- or Saving Mode
b. Operating keys
ON / OFF:
ON / OFF key
(For ON, press 1 sec.)
UNIT:
- Press shortly: Select unit:
N, kg or lb
ZERO:
Three functions:
- Zeros the measuring result (Tara function)
- Cleans the peak value (in Peak mode)
- Saves a setting (in SET mode)
SET:
- 1 x Press: Upper Limit [HidT]. To change
press: ▲ or (see section c.)
- 1 x Press: Lower Limit [LodT]. To change
press ▲ or ▼ (see section c.)
- 1 x Press: Minimum limit to save peak
values in the instrument’s memory.
[LE.SET]. Please see section „Min Limit
Peak Save“. To change press: ▲ or
(Only in „Peak-Mode“active) (see section
g.)
- 1 x Press: Auto-Off Function. Turns the
instrument off after a here defined time
period in sec. [P.OFF]. To change press: ▲
or ▼ (Only in „Battery-Mode“ active)
- 1 x Press: Peak-Freeze-Time [PE.2E /
A.PE / HoldT]: Time period in which a peak
value is being shown in the display in sec.
To change press: ▲ or ▼
1 x Press: Saves the Settings
PEAK:
Three functions
- Track mode (continuous measurement)
- Peak mode (capture of maximum values)
- Auto-Peak mode, same as Peak-mode, only
without the „Min limit peak save“ function
HidT
Lo dT
LESET
P.OFF
Page view 0
1 2 3 4

Summary of Contents

Page 1 - Instruction Manual

Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Tel: +49-[0]7433- 9933-199 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com In

Page 2 - ◘ OK OK

Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Tel: +49-[0]7433- 9933-199 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com In

Page 3

Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Tel: +49-[0]7433- 9933-199 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com In

Page 4

Sauter GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Tel: +49-[0]7433- 9933-199 Fax: +49-[0]7433-9933-149 Internet: www.kern-sohn.com In

Comments to this Manuals