KERN & Sohn GmbH Ziegelei 1 D-72336 Balingen E-Mail: [email protected] Phone: +49-[0]7433- 9933-0 Fax: +49-[0]7433-9933-149 Internet: www.kern-
7.1 Operation limits • The weighing bridges are designed extremely robust. However the load limits according to the following table should not be e
8 Service, maintenance, disposal Before any maintenance, cleaning and repair work disconnect the appliance from the operating voltage. 8.1 Daily ch
8.5 Instant help In case of an error in the program process, briefly turn off the balance and disconnect from power supply. The weighing process mus
9 Service documentation • This chapter is only intended for a balance specialist! • The weighing bridges are carried out in DMS sensor technology,
9.2 Check and adjustment of the corner load Check of the corner load: • Place the test weights in the centre of the load plate and tare. • The
1. 2. 3. 4. Adjustment of weighing cell J2 takes place at the potentiometer VR1. Adjustment of weighing cell J3 takes place at the potentiometer
10 Preload, Deadload and Overload settings Kern model Deadload** (kg) **= already applied preload Center Overload Protection circa (kg) Corner Ove
GB KERN KFP V40 Version 1.2 10/2014 Installation instructions weighing bridge Contents 1 General ...
1 General These installation instructions contain all data necessary for placing and commissioning the weighing bridge KERN KFP 1500V40M. 2 Technica
3.4 Warranty Warranty claims shall be voided in case • Our conditions in the operation manual are ignored • The appliance is used outside the descr
4 Basic Safety Precautions 4.1 Pay attention to the instructions in the Operation Manual Carefully read this operation manual before setup and com
6 Unpacking, Setup and Commissioning 6.1 Installation Site, Location of Use The weighing bridges are designed in a way that reliable weighing result
6.2 Unpacking, Scope of delivery CAUTION + Danger for the back! The weighing bridge is relatively heavy. Always use a suitable lifting device to li
6.3 Assembly, levelling Accurate weighing results require a weighing bridge with perfect horizontal alignment. During initial installation and after
6.4 Connecting a display unit Attention Put the connecting cable to the display unit in a manner that it is protected against damage. Description